• DC-DC Battery Charger MPPT Battery to Battery Inverter
  • DC-DC Battery Charger MPPT Battery to Battery Inverter
  • DC-DC Battery Charger MPPT Battery to Battery Inverter
  • DC-DC Battery Charger MPPT Battery to Battery Inverter
  • DC-DC Battery Charger MPPT Battery to Battery Inverter
  • DC-DC Battery Charger MPPT Battery to Battery Inverter

DC-DC Battery Charger MPPT Battery to Battery Inverter

Rated Power: 24V-310W, 1300W
Charging Current: 12V/6A, 50A
Input Voltage: 12-24/12V, 24V(21-32V)
Samples:
US$ 225/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
DC-DC Battery Charger MPPT Battery to Battery Inverter pictures & photos
DC-DC Battery Charger MPPT Battery to Battery Inverter
US $209-225 / Piece
Min. Order: 1 Piece
Gold Member Since 2010

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Manufacturer/Factory

Basic Info.

Model NO.
B2B242450
Type
Lead-Acid Battery Charger, Ni-CD Battery Charger
Charging Type
Solar Charger, Solar Charger
Principle
Half-Bridge Charger, Intelligent Charging
B2b Charging Current
24V, 50A
Max.Charging Power
1300W
Charge Battery Type
Gel, Sealed, Flooded, LiFePO4, Lithium-Ion
APP
Support
Bluetooth
Support
Output Voltage
24V(21-32V)
Transport Package
Neutral
Specification
neutral
Trademark
OEM
Origin
Shenzhen
Production Capacity
50000

Product Description

DC-DC Battery charger MPPT Battery to Battery Inverter

 Features
This is a all-automatic DC-DC battery charger, you can use the battery (12V) to charge the battery (12V) (B2B), specially designed for RVs, exposed cars, campers, ships, etc.
B2B126030: 12V-12V/60A BS123020: 12V-12V/30A

Technical Data
 
   
Main battery " Bord "  
Lead-Acid, Gel, AGM Batteries Nominal Voltage 12V
LiFePO4 Nominal Voltage 12.8V
lithium- ion( NCM) Nominal Voltage 11.1V
Capacity (Battery Size), recommended: 45-280AH
Vehicle Starter Battery "Start II":  
Vehicle Starter Battery Nominal Voltage: 12V
Min. Battery Capacity (Size), recommended: 60AH
12 V / 12 V B2B Charging operation  
Input Voltage Range "Start II" ,"D+" controlled: 10.5-16V
Maximum charging power: 650W
" Bord " Max. charge current 30A
Activation Control Input "D+" 8-16V
Signal Output "OK/TR", Switch Position "TR",
Cutoff Relay Bypass/max
12V/1A
Signal Output "OK/TR", Switch Position "OK" 12V/1A
Input "T T" for Battery Temperature Sensor "Board I": YES
" Ss-" "Ss+" Inputs Sensor Cables "-" and "+" for Battery "Board I": YES
stand-by current 24mA
Main battery overvoltage protection 15.5V
weight 1.44kg
demension 190×194×70mm
Operating temperature -20-50ºC

B2B Operation

mobile operation from dynamo and starter battery (Battery to Battery):

it refers to charging the main battery through dynamo and starter battery, .If it is not used in the Vehicle , you can also use one battery (12V) to charge another
  1. . The efficient charging converter (booster) allows full charging of the board battery during driving.
  2. . It increases/reduces the voltage to the level, which is required for precise charging of the board battery with the optimum characteristic line of charging.
  3. . The simultaneously supplied 12 V consumers are protected against overvoltage and voltage fluctuations.

Further Characteristics of the Unit
 
  • The output voltage is stabilized, free of peaks, smoothed and filtered.
  • Galvanic isolation between input and output:
  • No overvoltage at the output and thus protection of the consumer if the ground line is lost.
  • Clean, undisturbed mass ratios, even with long supply lines.
  • Stable operating voltage on site in mobile operation, e.g. Containers, trailers, roll containers etc.
  • Filtering and suppression of disturbances on the input to the output side.
  • Fully automatic continuous operation: The DC-DC converter can constantly work with the battery
  • Surveillance-free operation: multiple protection against overload, overheating, over voltage, short circuit, Misconduct and deep discharge of the battery through electronic regulation to complete
  • Switch off by built-in safety switch.
DC-DC Battery Charger MPPT Battery to Battery InverterDC-DC Battery Charger MPPT Battery to Battery InverterDC-DC Battery Charger MPPT Battery to Battery Inverter

Security guidelines

Intended use:
The DC-DC converter was built on the basis of the valid safety guidelines. The use may only be:
  1. On lead-acid, lead-gel or lead AGM or LiFePO4 batteries of the specified nominal voltage.
  2. With the specified cable cross-sections for inputs and outputs.
  3. With fuses of the specified strength near the battery to protect the wiring between the batteries and DC-DC converter connections.
5. In a well-ventilated room, protected against rain, moisture, dust and aggressive battery gases as well as in a non-condensing environment.
The device must never be used in places where there is a risk of gas or dust explosion consists!
DC-DC Battery Charger MPPT Battery to Battery InverterDC-DC Battery Charger MPPT Battery to Battery InverterDC-DC Battery Charger MPPT Battery to Battery InverterDC-DC Battery Charger MPPT Battery to Battery InverterDC-DC Battery Charger MPPT Battery to Battery InverterDC-DC Battery Charger MPPT Battery to Battery InverterDC-DC Battery Charger MPPT Battery to Battery InverterDC-DC Battery Charger MPPT Battery to Battery InverterDC-DC Battery Charger MPPT Battery to Battery Inverter


Installation of the Unit
  1. . Install the charger near the board supply battery I (for short charging cables) at a clean, even and hard mounting surface,which is protected from moisture, humidity and aggressive battery gases. The unit can be installed in any position.
  2. . To be installed in a moisture-proof, water-proof place, corrosion-proof place
  3. . When the charging controller is working, the fan will bring out heat, so when installing, ensure that there is at least 10cm of space behind the charger controller
  4. . Choose the appropriate cable specifications, length and fuse specifications, reverse connection of the battery will cause serious damage to the eq

Why Choose us?

> Oxiang is located in Shenzhen, China, a new type of city in rapid development. We focus on CCTV Camera researching and manufacturing from 2006;

> Sales person provide Pre-sales and after-sales service; Professional engineers are always standby and assist offer solutions;

> Cooperate with multiple departments to complete raw material procurement, production, inspection, delivery and other steps;

> The product comes with a one-year warranty.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
DC-DC Battery Charger MPPT Battery to Battery Inverter pictures & photos
DC-DC Battery Charger MPPT Battery to Battery Inverter
US $209-225 / Piece
Min. Order: 1 Piece
Gold Member Since 2010

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Manufacturer/Factory
Management System Certification
ISO 9001, ISO 14001, ISO 14000, ISO 14064, QC 080000, BSCI
OEM/ODM Availability
Yes